12V solar panels charging kits for caravans, motorhomes, boats, yachts, marine

Tel.:+44 (0) 203 150 11 11

Fax:+44 (0) 203 150 12 12

Email:

  • Twitter
  • Facebook
  • Skype
  • Whatsapp
Free UK delivery
  • Items:
    0
  • Total:
    £ 0.00

TELL A FRIEND ABOUT THIS PRODUCT

Testimonials:

The panels are amazing.........we run the boat fridge all day and have spare amps on top

David (Southville, Bristol, UK)

We are a trusted supplier to thousands of UK clients

We are a trusted supplier to thousands of UK clients

UPS Systems

8kW Uninterrupted Power Supply (UPS) System with 19.2kWh energy storage

8kW Uninterrupted Power Supply (UPS) System with 19.2kWh energy storage
8kW Uninterrupted Power Supply (UPS) System with 19.2kWh energy storage
8kW Uninterrupted Power Supply (UPS) System with 19.2kWh energy storage
8kW Uninterrupted Power Supply (UPS) System with 19.2kWh energy storage

Phone order?

Call our number
0203 150 1111
and quote the product code below
(have your card and delivery details ready)
Working hours Mon-Fri 9am-6pm
Product code:
UPS2-KMS4K-48
Ex. VAT £4908.33
Inc. VAT £5889.99
Availability:
Out of stock
Add to shopping cart

 

This Photonic Universe Uninterrupted Power Supply (UPS) system is suitable for both mains-powered and off-grid applications where a stable and reliable source of AC power is required. Ideal for running household appliances, IT and computer rooms, servers, commercial or other large electronic equipment.

In a mains-powered setup, the system ensures that the AC appliances are not interrupted even if the mains electricity is unstable, intermittent or the power is suddenly cut off. While the mains power is available, the system links it to the AC output to power connected appliances whilst simultaneously charging the batteries, or keeping them topped up. If the mains power is suddenly cut off, the system instantly transfers the power input to the batteries and starts drawing energy from them so that the load work is not interrupted. When the mains AC input power becomes available again, the system transfers the input to mains AC power.

For off-grid systems with a generator, this UPS system can allow for continual power even when the generator is turned off. This allows users to achieve significant savings of fuel costs by only running the generator periodically - at the optimal power levels to charge the batteries.

Featuring a dry contact port, the inverters can activate or deactivate relay switches or compatible generators automatically when the battery voltage falls below a user-defined level. For off-grid systems with a generator, this feature is useful as the relay can activate the generator to start charging the batteries when they are low.

The system can also be used for portable power applications, i.e. when the batteries are charged in a location with mains electricity, and the system is then transported to a different off-grid location to provide power on demand on a temporary basis. 

This UPS system also supports solar power input with no additional charge control equipment required. Users can simply connect a suitable solar array to start charging from solar power to save on electricity bills for mains connected systems, or in order to run a generator less frequently for off-grid systems.

The system can be easily expanded to generate up to 36kW of continuous power, by connecting up to 9 inverters in parallel (additional parallel kits required, one per inverter). The external battery bank allows for easy expansion or replacement, as well as straight-forward installation in irregular locations.

This package includes 2 x UPS units, 2 x parallel connection kits, 8 x 200Ah gel deep-cycle batteries, 4m tinned copper battery cables, battery linking cables, 2 x thermal over-current circuit breakers and loose ring terminals for crimping.

Please note: the inverter uses predictive cooling logic to activate the fans, and is not suitable for installing in locations where silence is required.

Click on the Details and Specifications tab for more information about this kit.

 

UPS specifications (per unit):

  • Nominal battery voltage: 48V
  • Continuous power output: 4000W / 4000VA (220-240V AC)
  • Surge power: 8000VA
  • Output frequency: 50Hz /60 Hz
  • Output waveform: Pure sine wave
  • Maximum solar input power: 4000W
  • Maximum open circuit solar input voltage: 145V
  • Solar MPPT operating voltage: 60-115V DC
  • Maximum solar charging current: 80A
  • Maximum mains AC charging current: 60A
  • Maximum combined charging current: 140A
  • Peak efficiency: 93%
  • Solar / AC charger max efficiency: 98%
  • Operating temperature: 0°C to 55°C
  • Supplied with a PC connection cable and PC software CD
  • Paralleled operation with up to 8 further units, using a parallel connection kit(s)
  • Size: 120 x 295 x 468 mm
  • Weight: 12.5 kg

 

Battery specifications (per battery):

  • Nominal voltage: 12V
  • Nominal capacity: 200Ah (10h rate) / 205Ah (20h rate)
  • Maximum charging current: 40A
  • Self-discharging rate: <1% per month
  • Cycle lifetime at 30% D.O.D.: 1200-1300
  • Pressure control: safety valve installed
  • Terminal type: F24 (bolts and washers included)
  • Operating temperature: from -10C to +50C
  • Size: 523 x 239 x 243 mm
  • Weight: 61.5 kg

 

Please note: due to our warehouse arrangements, the accessories may be shipped from a different warehouse to the hybrid inverters and batteries, and therefore delivered in a separate package.

The batteries are covered by a 1 year repair or replacement warranty provided by Photonic Universe. In the unlikely event that a defect is found and confirmed during this period, we guarantee that we will repair or replace defective items (at our discretion). The hybrid inverters are covered by a 1 year manufacturer warranty. For more information please refer to our Terms and Conditions.

For installation advice, please click on the Installation tab.

 

Please note: this UPS system uses off-grid inverters. Any other AC power sources, including mains, can only be connected to the inverters' input AC terminals, and should be fully isolated from the inverters' output AC terminals. If the AC outputs of the inverters come into contact with another source of AC power, the inverters will be damaged.

If you need help with installation or have any technical questions we can provide FREE support - please contact us by email or phone (see Contact Us page for more information).